The function provides the analysis of cross-talk measurements on a FI lexsyg SMART reader using Al2O3:C chips
Arguments
- object
RLum.Analysis (required): measurement input
- signal_integral
numeric (optional): signal integral, used for the signal and the background. If nothing is provided the full range is used
- dose_points
numeric (with default): vector with dose points, if dose points are repeated, only the general pattern needs to be provided. Default values follow the suggestions made by Kreutzer et al., 2018
- recordType
character (with default): input curve selection, which is passed to function get_RLum. To deactivate the automatic selection set the argument to
NULL
- irradiation_time_correction
numeric or RLum.Results (optional): information on the used irradiation time correction obtained by another experiments.
- method_control
list (optional): optional parameters to control the calculation. See details for further explanations
- plot
logical (with default): enable/disable plot output
- ...
further arguments that can be passed to the plot output
Value
Function returns results numerically and graphically:
———————————–[ NUMERICAL OUTPUT ]
———————————–
RLum.Results
-object
slot: @data
Element | Type | Description |
$data | data.frame | summed apparent dose table |
$data_full | data.frame | full apparent dose table |
$fit | lm | the linear model obtained from fitting |
$col.seq | numeric | the used colour vector |
slot: @info
The original function call
————————[ PLOT OUTPUT ]
————————
An overview of the obtained apparent dose values
How to cite
Kreutzer, S., 2024. analyse_Al2O3C_CrossTalk(): Al2O3:C Reader Cross Talk Analysis. Function version 0.1.3. In: Kreutzer, S., Burow, C., Dietze, M., Fuchs, M.C., Schmidt, C., Fischer, M., Friedrich, J., Mercier, N., Philippe, A., Riedesel, S., Autzen, M., Mittelstrass, D., Gray, H.J., Galharret, J., Colombo, M., 2024. Luminescence: Comprehensive Luminescence Dating Data Analysis. R package version 0.9.26. https://r-lum.github.io/Luminescence/
References
Kreutzer, S., Martin, L., Guérin, G., Tribolo, C., Selva, P., Mercier, N., 2018. Environmental Dose Rate Determination Using a Passive Dosimeter: Techniques and Workflow for alpha-Al2O3:C Chips. Geochronometria 45, 56-67. doi: 10.1515/geochr-2015-0086
Author
Sebastian Kreutzer, Institute of Geography, Heidelberg University (Germany) , RLum Developer Team
Examples
##load data
data(ExampleData.Al2O3C, envir = environment())
##run analysis
analyse_Al2O3C_CrossTalk(data_CrossTalk)